Measuring Pharmacovigilance Compliance: KPIs, EMA Monthly Notifications and the Quality System

Since late 2025, the European Medicines Agency has been sending marketing authorisation holders monthly reports on how many of their individual case safety reports (ICSRs) reached EudraVigilance late. Timeliness is no longer something a company only discovers during an inspection: it is measured centrally, every month. For QPPVs and pharmacovigilance managers, the question is whether their own quality system measures it first.

What the EMA compliance notifications cover

EMA began compliance monitoring based on the reporting timelines in the pharmaceutical legislation in September 2025, starting with the highest-volume senders and extending to all organisations from December 2025. The reports are generated from EudraVigilance data and sent to the QPPV or responsible person of each sender organisation, normally at the start of each month, covering the previous month’s submissions.

  • Serious ICSRs are measured against the 15-day deadline and non-serious ICSRs against the 90-day deadline.
  • For clinical trial sponsors, SUSARs are measured against the 7- and 15-day deadlines.
  • Each report shows the proportion and number of on-time and late cases, with a list of the late cases.

EMA has said that companies are not expected to reply to every monthly report, and that EMA or national competent authorities will make contact if there are particular issues. In practice, a pattern of late reporting now sits in a regulator’s inbox long before any inspection is planned.

The legal basis: a quality system that monitors itself

GVP Module I and Commission Implementing Regulation (EU) No 520/2012 require the marketing authorisation holder to operate a pharmacovigilance quality system with documented procedures, including processes to submit accurate and verifiable data within the legal time limits. The 2025 amendment, Implementing Regulation (EU) 2025/1466, fully applicable since 12 February 2026, sharpened several related expectations:

  • Quality system audits should cover all pharmacovigilance activities of the company and its subcontractors, at risk-based intervals.
  • Contracts with service providers must describe roles, safety data exchange and arrangements for audit and inspection.
  • Only major and critical deviations now need to be documented in the PSMF, which makes a robust internal deviation and trending process more, not less, important.

Choosing indicators that mean something

A useful compliance dashboard goes beyond the single figure EMA reports. Indicators worth tracking typically include:

  • ICSR submission timeliness, split by serious and non-serious, by source and by partner.
  • Day-zero accuracy: whether affiliates, medical information, market research and partners pass on safety information promptly.
  • Aggregate report timeliness for PSURs and RMP updates against the EURD list and agreed dates.
  • Safety variation implementation: time from a PRAC or CMDh outcome to updated product information.
  • Signal management milestones, CAPA closure and overdue training.

Each indicator needs a defined owner, a target, a frequency of review and an escalation route to the QPPV and senior management.

From late cases to root causes

A late ICSR is a symptom. Reconcile EMA’s figures with your own safety database, then trace each late case back to where time was lost: an affiliate in-tray, a partner exchange, a literature screening gap or a gateway rejection. Recurring patterns should become deviations with root cause analysis and CAPA, and the trend should feed the next audit plan. Inspectors increasingly ask not only “were you late?” but “did you notice, and what did you do?”

How PQRA helps

PQRA supports marketing authorisation holders in Greece and across the EU with pharmacovigilance compliance: designing KPI frameworks aligned with GVP Module I, reconciling EMA compliance reports with safety databases, investigating late reporting, reviewing partner agreements against the 2025 amendments and preparing for audits and inspections. Our QPPV and local contact person services build this monitoring in from day one.

Talk to PQRA about strengthening your pharmacovigilance compliance monitoring →